Aeotec Water Sensor 7 Pro Manuale d'uso - Pagina 9

Sfoglia online o scarica il pdf Manuale d'uso per Accessories Aeotec Water Sensor 7 Pro. Aeotec Water Sensor 7 Pro 14. Water sensor
Anche per Aeotec Water Sensor 7 Pro: Manuale (3 pagine), Manuale di avvio rapido (8 pagine), Manuale d'uso (9 pagine), Manuale d'uso (13 pagine), Manuale d'uso (9 pagine)

Aeotec Water Sensor 7 Pro Manuale d'uso
AEOTEC User Manual
Screw Terminal
The product must support the interconnection of external binary sensors as well as actuators and dry-
contacts. The product allows interconnection with external sensors/actuators via 3-pin screw terminals
with the following pinout:
• #1: Ground
• #2: Digital Input
• #3: VCC (direct battery supply)
VCC + Ground terminals can be used to externally power the sensor with a 3.6V battery or special
power adapter (which is not included in the scope of delivery). Digital + VCC is used to connect the
external dry contact.
Link testing
When activated by configuration parameter #5 the device can perform a link test with device No.1. Double-clicking the
tamper will start the process. As a result, the GREEN LED will blink two times in case of success and the RED LED will
blink two times in case of failure.