For details about connection settings, please see the following illustrated manuals.
(IP Connection):
"Controlling AW-HE40 via AW-RP50
(Serial Connection):

【Controlling Multiple AW-HE40 Cameras via AW-RP50 Controller】

Connecting multiple cameras is usually done by "AUTO SET IP" which is executed via AW-RP50
controller.
The controller detects the cameras in the same subnet (a range divided by a router), links them to the
camera numbers where [NoAsign] is set, and then automatically assigns pre-registered IP addresses to
those cameras.
Connection Setting: [SYSTEM] menu > [CAMERA CTL] > [CAM1 – 100] ⇒ [NoAsign]
IP Address Setting: [SYSTEM] menu > [CAM IP ADR] > [CAM1 – 100] ⇒ [Registered IP Address]
Example:
AW-RP50 detects Cameras A, B and C.
[CAMERA CTL] → [NoAsign] for all of [CAM1 – 3]
[CAM IP ADR] → If the following are IP addresses of [CAM1 – 3],
CAM1: 192. 168. 0. 10
CAM2: 192. 168. 0. 11
CAM3: 192. 168. 0. 12
IP addresses of the cameras are set up as follows.
Camera A: 192. 168. 0. 10 *Controlled via AW-RP50/CAM1
Camera B: 192. 168. 0. 11 *Controlled via AW-RP50/CAM2
Camera C: 192. 168. 0. 12 *Controlled via AW-RP50/CAM3
Press MENU button. – (Fig. 3-A)
② Press [10] SYSTEM button. – (Fig. 3-B)
③ Turn F1 dial – (Fig. 3-C) to select [5] AUTO SET IP.
④ Press F1 dial to make [RENEW IP ADR] appear on the lower half of the LCD screen.
*If it does not appear, turn F2 dial – (Fig. 3-D) to make [RENEW IP ADR] appear.
⑤ While [RENEW IP ADR] is displayed, press F2 dial. The number of units AW-RP50 has newly
detected and the number of units it currently manages (all the remote cameras and switchers) will be
displayed on the upper half of the LCD screen. (*1)
⑥ [NO] will be displayed on the lower half of the LCD screen. So, turn F2 dial to select [YES] and then
press F2 dial.
⑦ When [COMPLETE] is displayed on the lower half of the LCD screen, the setting-up is completed.
"Controlling AW-HE40 with AW-RP50 (via Serial
Controller"
Connection)"