21st Century Alarms LuxHome LCD Podręcznik użytkownika

Przeglądaj online lub pobierz pdf Podręcznik użytkownika dla System bezpieczeństwa 21st Century Alarms LuxHome LCD. 21st Century Alarms LuxHome LCD 7 stron. Wireless alarm system

LuxHome LCD
Wireless Alarm
System
Contents
About Your Alarm System

01. Full Arm

03. Part Arm 2
10. Event Log
19.
20.
User Guide
Page
01
01
01
02
02
02
02
03
03
03
03
04
04
04 + 05
06 + 07
08
09
09
09 + 10
10
11
12 + 13
LuxHome LCD Wireless Alarm
When leaving the premises, the system must be Armed. However, before doing so, check that all
windows are closed and locked, all protected doors are closed and PIR Detectors are not obstructed.
Ensure that pets are restricted to areas not protected by PIR Detectors.
The system has three arming modes, ARM, Part-Arm 1 and Part-Arm 2. The Part-Arm modes allow
for selected zones to be left in a Disarmed state while the reminder of the system is Armed.
When the system is Armed (in any mode) the Control Panel will display the arming mode and the
status of the Latch Key for a few seconds. If enabled, the system Exit-Delay will start and be
counted down on the display. As the Exit-Delay expires the Control Panel will beep, with the beep
rate increasing in steps as the delay expires. At the end of the Exit-Delay all active zones be Armed.
By this time the user must have left the property and closed the final exit door.
If while the system is armed a detector on an active zone is triggered, if enabled, the programmed
Entry-delay for that zone will start and be counted down on the display. As the Entry-Delay expires
the Control Panel will beep, with the beep rate increasing in steps as the delay expires. If the system
has not been disarmed when the Entry-Delay expires an alarm will occur. If however, the Entry-Delay
for the triggered zone has been disabled an alarm will occur immediately.
At the end of the programmed alarm duration the Siren and Control Panel alarms will stop and the
system will automatically re-Arm.
01 - Full Arm
The system can be set in ARM mode using either the Remote Control or the Control Panel as
follows:
Remote Control: Press the 'ARM' button
Control Panel: Press the Arm button followed by the User Password and then the Enter button:
?
?
?
?
,
,
User Access Code
By pressing
button, the programmed exit delay will be overrided to 5 seconds.
02 - Part-Arm 1
The system can be set in PART-Arm 1 mode using either the Remote Control or the Control Panel
as follows:
Remote Control: Press the 'PART-ARM' button
?
?
?
,
Control Panel:
User Access Code
By pressing
button, the programmed exit delay will be overrided to 5 seconds.
.
.
?
,
Page 01