21st Century Alarms LuxHome LCD Podręcznik użytkownika - Strona 4

Przeglądaj online lub pobierz pdf Podręcznik użytkownika dla System bezpieczeństwa 21st Century Alarms LuxHome LCD. 21st Century Alarms LuxHome LCD 7 stron. Wireless alarm system

14 - Testing The Alarm System
The Control Panel has a programmed test routine. You may test the system at any time, however it
is recommended that the system is tested at regular intervals not exceeding 3 months.
With the system in Standby Mode
Press
. This puts the system into Test Mode.
User Password
The Arm and Part-Arm LEDs will flash.
The system is now in the Test Mode.
Use the
and
buttons to scroll through the menu and press
test function or sub-menu.
Note: After completing all required test functions, press
Standby.
Walk Test
Before commencing testing, please ensure that there is no movement in any PIR protected area, all
doors/windows protected by Magnetic Contact Detectors are closed and that all battery covers and
housings are correctly fitted.
Scroll through the top level Test Mode menu until 'Walk Test' is displayed and press
'Walk Test Waiting...' will be displayed.
1. Trigger each detector on the system by either walking into a PIR protected area or by opening a
door/window protected by a Magnetic Contact detector. As each detector is triggered the Control
Panel will chime to indicate that an alarm signal has been received and the identity of the zone
that the detector is configured for will be displayed.
2. Operate detector anti-tamper switches by opening the case of the device. As the switches are
operated the Control Panel will chime and 'Accessory Tamper' will be displayed.
3. Activate each button on the Remote Control in turn. As each button is pressed the Control Panel
will chime and the button name will be displayed. (e.g. 'REMOTE CONTROL DISARM').
Press
to exit Walk Test and return to the top level Test Mode menu.
ESC!
to select the displayed
, ,
,
to leave Test mode and return to
ESC!
, ,
,
Page 06
14 - Testing The Alarm System
Alarm Test
Scroll through the top level Test Mode menu until 'Alarm Test' is displayed and press
Scroll though the menu until the required alarm displayed and press
alarm for 5 seconds.
Select 'Wirefree Siren Test' to operate the External Solar Siren.
Select 'Hardwired Siren Test' to operate the Control Panel Siren and external hardwired Siren (if
connected).
Select 'Relay Test' to operate the External hardwired (N.O./N.C.) relay contacts (if connected).
Press
to exit Alarm Test and return to the top level Test Mode menu.
ESC!
Wirefree Siren Service On/Off
Scroll through the top level Test Mode menu until 'Wirefree Siren Service ON/OFF' is displayed
and press
.
,
This offers the flexibility of removing or changing siren's battery. Wait for 10 seconds until ON/OFF
duration has elapsed, then go ahead with fixing the siren as desired.
Voice Dialer Test
.
Scroll through the top level Test Mode menu until 'VOICE DIALER TEST' is displayed and press
.
,
In order to test the voice dialer properly, the prerequisite is to set the telephone number, record the
message and enable the call routing in the programming mode.
When testing is in progress, simply press
If 'Line Status' LED is flashing, it implies bad telephone line connection or telephone network being
out of order. Check the telephone line and re-test it.
Digital Dialer Test
Scroll through the top level Test Mode menu until 'Digital Dialer Test' is displayed and press
.
In order to test the digital dialer properly, the prerequisite is to set the telephone number and unit ID
number in the programming mode.
When testing is in progress, simply press
If 'Line Status' LED is flashing, it implies two causes of failure. One is bad telephone line connection
or telephone network being out of order. The other cause of failure is derived from the central
monitoring station. Consult with the central monitoring station for help.
, ,
,
to operate the selected
, ,
,
to stop testing.
ESC!
, ,
to stop testing.
ESC!
Page 07
.
,