e-survey E500 Kullanıcı Kılavuzu - Sayfa 13

Alıcı e-survey E500 için çevrimiçi göz atın veya pdf Kullanıcı Kılavuzu indirin. e-survey E500 19 sayfaları.
Ayrıca e-survey E500 için: Manuel (19 sayfalar)

e-survey E500 Kullanıcı Kılavuzu

3.5.2 MEMS Tilt Survey

When MEMS sensor is activated on E500. To calibrate the MEMS sensor, receiver
must be in Fixed solution. In SurPad4.0 software, connect device and click "Device" ->
"Device Settings", enable "Pole Tilt Correction" function. Then, go to "Survey" ->
"Point Survey" page. The software will guide user to calibrate the sensor.
Input the correct pole height
Draw circle on the ground using the pole
Follow the guide and shake the pole back and forth for around 5-10 seconds or
walk in straight line around 10 meters until it shows "Ready"
Web:
www.esurvey-gnss.com
E500 User Manual