3.5.2 MEMS Tilt Survey
When MEMS sensor is activated on E500. To calibrate the MEMS sensor, receiver
must be in Fixed solution. In SurPad4.0 software, connect device and click "Device" ->
"Device Settings", enable "Pole Tilt Correction" function. Then, go to "Survey" ->
"Point Survey" page. The software will guide user to calibrate the sensor.
•
Input the correct pole height
•
Draw circle on the ground using the pole
•
Follow the guide and shake the pole back and forth for around 5-10 seconds or
walk in straight line around 10 meters until it shows "Ready"